GENERAL SPECIFICATIONS :
Power supply : 230Vac +-10%, 50Hz – maximum
protection 16A/2P
Insulation voltage : 3KV tested
Characteristic consumption : 2.8VA
Ambient temperature :
Working temp. range : 10°C to 50°C
Storage temp. range : -10°C to 60°C
Maximum humidity : 93%, no moisture
condensation
Bus load : 10mA at nominal 13,8V
Internal fuse : 6,3AT single-phase
Max installation altitude : 2.000m
OUTPUTS : UP1/2 – DN1/2 : 230V
UP1 – DN1 and UP2 – DN2 : internally locked
contacts
Contact resistance :470m
2 OUTPUTS 8AMP. 2 IINPUTS SHUTTER MODULE
In a Qbus system, motor control (for shutters, screens,…) can be done centrally (from the electrical distribution board) or decentrally (with a module on the bus closeby the motor).
Your custom content goes here. You can add the content for individual product
Related products

The range of Qbus dimmermodules goes from standard dimmers to dim halogene or incandescent lights over universal dimmers for any load to 0/1-10V dimmers to dim analogue circuits or energy savings lamps
2 OUTPUTS 10-500VA, 3 INPUTS UNIVERSAL RELAY MODULE

The range of Qbus dimmermodules goes from standard dimmers to dim halogene or incandescent lights over universal dimmers for any load to 0/1-10V dimmers to dim analogue circuits or energy savings lamps.
1 OUTPUT 0/1-10V ANALOG OUTPUT MODULE

The CTD Controller (Patent Pending) is the heart of your QBus system. The Controller controls and supplies power to all Qbus modules connected via the usual two-wire bus: flexible and easy to install. Each controller has an on-board SD memory card on which all actions that happen on the bus are stored. That data can be used by the Qbus EQOmmand software to visualize, predict and optimize energy consumption. Each CTD has a standard USB port to adapt your system to your liking in an easy way. Optionally, each controller can have an Ethernet port via which you can securely communicate with your controller over the internet.
CONTROLLER USB & ETHERNET

Module which counts and processes pulses received from a pulse meter. Any pulse meter can be connected to the ECM04 as long as the contacts are potential-free. The ECM04 can receive a pulse every 250ms. Alarms can be triggered based on a set number of pulses, for example to receive green energy certificates every kW generated by solar panels.
ENERGY COUNTER MODULE

The CTD Controller (Patent Pending) is the heart of your QBus system. The Controller controls and supplies power to all Qbus modules connected via the usual two-wire bus: flexible and easy to install. Each controller has an on-board SD memory card on which all actions that happen on the bus are stored. That data can be used by the Qbus EQOmmand software to visualize, predict and optimize energy consumption. Each CTD has a standard USB port to adapt your system to your liking in an easy way. Optionally, each controller can have an Ethernet port via which you can securely communicate with your controller over the internet.