GENERAL SPECIFICATIONS :
Power supply : bus
Ambient temperature :
Working temp. range : 10°C to 50°C
Storage temp. range : -10°C to 60°C
Maximum humidity : 93%, no moisture
condensation
Bus load :
At rest: 5mA without LEDs, 8mA with
LEDs at nominal 13,8V
During activation: 16mA without LEDs,
20mA with LEDs at nominal 13,8V
Max installation altitude : 2.000 meters.
OUTPUTS :
UP – DN: Up – Down contacts for motor control
Rated current : 3,5A inductive
A bipolar automatic fuse of maximum 6A must be
placed on the mains power.
Contact resistance : 30m
Endurance : min. 100,000 operations
Rated load :
Resistive load (cos = 1)
8A at 230Vac
8A at 30Vdc
Inductive load (cos = 0,4; L/R = 7 ms)
3,5A at 230Vac
3,5A at 30Vdc
Maximum switching power :
Resistive load (cos = 1)
2 UP/DOWN OUTPUTS 230V SHUTTER MODULE WITH POSITIONING
In a Qbus system, motor control (for shutters, screens,…) can be done centrally (from the electrical distribution board) or decentrally (with a module on the bus closeby the motor).
Your custom content goes here. You can add the content for individual product
Related products
The range of Qbus dimmermodules goes from standard dimmers to dim halogene or incandescent lights over universal dimmers for any load to 0/1-10V dimmers to dim analogue circuits or energy savings lamps.
4 OUTPUTS 10-500VA, 5 INPUTS UNIVERSAL RELAY MODULE
Module which counts and processes pulses received from a pulse meter. Any pulse meter can be connected to the ECM04 as long as the contacts are potential-free. The ECM04 can receive a pulse every 250ms. Alarms can be triggered based on a set number of pulses, for example to receive green energy certificates every kW generated by solar panels.
ENERGY COUNTER MODULE
The range of Qbus dimmermodules goes from standard dimmers to dim halogene or incandescent lights over universal dimmers for any load to 0/1-10V dimmers to dim analogue circuits or energy savings lamps.