GENERAL SPECIFICATIONS :
Power supply : bus
Ambient temperature :
Working temp. range : 10°C to 50°C
Storage temp. range : -10°C to 60°C
Maximum humidity : 93%, no moisture
condensation
Bus load :
At rest: 5mA without LEDs, 8mA with
LEDs at nominal 13,8V
During activation: 16mA without LEDs,
20mA with LEDs at nominal 13,8V
Max installation altitude : 2.000 meters.
OUTPUTS :
UP – DN: Up – Down contacts for motor control
Rated current : 3,5A inductive
A bipolar automatic fuse of maximum 6A must be
placed on the mains power.
Contact resistance : 30m
Endurance : min. 100,000 operations
Rated load :
Resistive load (cos = 1)
8A at 230Vac
8A at 30Vdc
Inductive load (cos = 0,4; L/R = 7 ms)
3,5A at 230Vac
3,5A at 30Vdc
Maximum switching power :
Resistive load (cos = 1)
2 UP/DOWN OUTPUTS 230V SHUTTER MODULE WITH POSITIONING
In a Qbus system, motor control (for shutters, screens,…) can be done centrally (from the electrical distribution board) or decentrally (with a module on the bus closeby the motor).
Your custom content goes here. You can add the content for individual product
Related products

Input Modules exist in both DIN rail format to be mounted in the enclosure, as well as in a smaller format to be included in the in-wall mounting box of a switch. Via input modules, external contacts such as standard switches, window and door contacts, all kinds of detectors, garage doors and the like are connected to the Qbus system
2 INPUTS POTENTIAL FREE MODULE

The range of Qbus dimmermodules goes from standard dimmers to dim halogene or incandescent lights over universal dimmers for any load to 0/1-10V dimmers to dim analogue circuits or energy savings lamps.
5 INPUTS, 4 ANALOG DIMMERS AND 4RELAYS 16AMP./230V CONTROL MUDULE

In a Qbus system, motor control (for shutters, screens,…) can be done centrally (from the electrical distribution board) or decentrally (with a module on the bus closeby the motor).