GENERAL SPECIFICATIONS :
Power supply : 230Vac +-10%, 50Hz – maximum
protection 16A/2P .
This device is exclusively suitable for DIN-rail
mounting EN50022.
Insulation voltage : 3 kVac tested
Characteristic consumption : 4.5VA
Ambient temperature :
Working temp. range : 10°C to 70°C
Storage temp. range : -10°C to 70°C
Maximum humidity : 93%, no moisture
condensation
Bus load : 10mA at nominal 13,8V
Fuse : 500mAT single-phase
Max installation altitude : 2000meters
OUTPUTS :
1 – 4 : dimmable outputs for halogen, incandescent,
dimmable 230V LED and dimmable CFL lamps. Maximum load :
Incandescent / halogen with electronic transfo: max
500VA at 230Vac each circuit
Halogen with classic (magnetic) transfo max
400VA at 230Vac each circuit
4 OUTPUTS 10-500VA, 5 INPUTS UNIVERSAL RELAY MODULE
The range of Qbus dimmermodules goes from standard dimmers to dim halogene or incandescent lights over universal dimmers for any load to 0/1-10V dimmers to dim analogue circuits or energy savings lamps.
Your custom content goes here. You can add the content for individual product
Related products
CONTROLLER “FULL” WITH USB ETHERNET
The CTD Controller (Patent Pending) is the heart of your QBus system. The Controller controls and supplies power to all Qbus modules connected via the usual two-wire bus: flexible and easy to install. Each controller has an on-board SD memory card on which all actions that happen on the bus are stored. That data can be used by the Qbus EQOmmand software to visualize, predict and optimize energy consumption. Each CTD has a standard USB port to adapt your system to your liking in an easy way. Optionally, each controller can have an Ethernet port via which you can securely communicate with your controller over the internet.
CONTROLLER “MAXI” WITH USB ETHERNET
Module which counts and processes pulses received from a pulse meter. Any pulse meter can be connected to the ECM04 as long as the contacts are potential-free. The ECM04 can receive a pulse every 250ms. Alarms can be triggered based on a set number of pulses, for example to receive green energy certificates every kW generated by solar panels.
ENERGY COUNTER MODULE
In a Qbus system, motor control (for shutters, screens,…) can be done centrally (from the electrical distribution board) or decentrally (with a module on the bus closeby the motor).
2 UP/DOWN OUTPUTS 230V SHUTTER MODULE WITH POSITIONING
The range of Qbus dimmermodules goes from standard dimmers to dim halogene or incandescent lights over universal dimmers for any load to 0/1-10V dimmers to dim analogue circuits or energy savings lamps.
STANDALONE DALI BROADCAST
Input Modules exist in both DIN rail format to be mounted in the enclosure, as well as in a smaller format to be included in the in-wall mounting box of a switch. Via input modules, external contacts such as standard switches, window and door contacts, all kinds of detectors, garage doors and the like are connected to the Qbus system